Accredited NABL Scope & Services
Operating under ISO 2017 accreditation (Certificate CC-4341) and ALCOA+ data integrity principles across Permanent Laboratory and Site Facilities.
| S.No | Facility | Discipline | Measurand / Instrument | Calibration Method | Range | CMC (±) |
|---|
Comprehensive Calibration Scope (Key Parameters)
All measurements are traceable to National and International Nodal Laboratories with unbroken measurement traceability.
Pressure & Vacuum Calibration
Calibration of pressure gauges, vacuum sensors, differential pressure transmitters, and low pressure indicators using National Traceable Master Low Pressure Calibrators and Indicating Pressure Gauges.
Temperature & Thermal Calibration
NABL & ISO accredited calibration for RTD Pt-100 sensors, S-Type thermocouples, digital thermometers, dry block calibrators, and deep freezers (-80°C to 50°C).
Dimensional & Mechanical Calibration
Precision verification of Vernier calipers, micrometers, height/depth gauges, dial indicators, and test plugs using Caliper Checkers, '0' Grade Gauge Blocks, and Granite Surface Plates.
Weights & Weighing Scales Calibration
Calibration of analytical balances, precision industrial weighing scales, and mass comparators using calibrated E2 and F1 class standard stainless steel weights.
Electrical & Electro-Technical Calibration
Multi-parameter calibration for Digital Multimeters (DMMs), clamp meters, decade resistance boxes (0.01 Ω to 11.11 MΩ), power supplies, and process calibrators.
pH & Conductivity Calibration
Calibration and verification of benchtop and portable pH meters, conductivity meters, and TDS analyzers used in water purification and pharmaceutical quality control.
Thermal Validation Services (Controlled Environments)
Utilizing high-accuracy wireless data loggers (-40 to 70°C, 0-100% RH) and wired thermocouple data loggers (-80 to +1200°C) with national/international traceability.
Area & Warehouse Temperature Mapping
Multi-point 3D spatial mapping across large storage facilities
Walk-in type Stability Chamber Validation
0°C to 70°C and 0% to 100% RH loaded/unloaded qualification
Incubators & Refrigerators Validation
Uniformity and recovery testing for biological storage units
Cold Chamber / Cold Room Validation
Extended duration temperature distribution and door-open recovery studies
Autoclaves Steam Sterilizer Validation
Heat penetration and heat distribution studies with F0 lethality calculation
Ovens & Furnaces Thermal Profiling
High-temperature qualification for curing, drying, and annealing units
Need Comprehensive Thermal Mapping Protocol Preparation?
We execute complete IQ, OQ, PQ protocols with spatial 3D mapping reports, risk assessment, and deviation summaries tailored for regulatory inspections.
HVAC & Cleanroom Validation Scope (Testing Protocols)
Ensuring absolute environmental control and sterile processing conditions for pharmaceutical, biological, and electronic cleanrooms.
Airborne Particle Count (APC) Testing
Cleanroom classification and monitoring as per ISO 14644-1 standards using calibrated particle counters.
Filter Integrity Test (HEPA / ULPA)
PAO / DOP aerosol photometer testing to detect bypass, pinhole leaks, and filter efficiency in cleanrooms and biosafety cabinets.
Air Velocity & Uniformity Testing
Measurement of laminar flow speed across filters to verify face velocity and ensure contamination barrier integrity.
Air Flow Pattern & Visualization Studies
Smoke generation and video profiling to confirm laminar airflow direction and absence of stagnant turbulence pockets.
Air Balancing & ACH Calculation
Air Changes per Hour (ACH) verification and room differential pressure balancing across cascading containment zones.
LAF / RLAF Workstation Validation
Complete qualification of Laminar Air Flow and Reverse Laminar Air Flow dispensing booths and sampling hoods.
Master Instruments & Calibration Standards Table
Below is our comprehensive roster of 37+ master calibrators across 25 primary designations maintained in our Vasai (E) facility.
| S.No. | Master Instrument / Calibration Standard | Range / Specification & Accuracy | Calibration Agency / Traceability |
|---|---|---|---|
| 01 | Low Pressure Calibrator / Indicating Gauge | -1 to 40 bar / 0 to 700 bar | National Traceable |
| 02 | Low Pressure Calibrator | -1 to 20 bar | National Traceable |
| 03 | Indicating Pressure Gauge | 0 to 700 bar | National Traceable |
| 04 | Vacuum Gauge Standard | -1 to 0 bar | National Traceable |
| 05 | Digital Thermometer with RTD Pt-100 | -199.99°C to 199.99°C / -200°C to 850°C | International Traceable / ERTL (W) |
| 06 | Temperature Master Sensors | -80°C to 300°C | International Traceable |
| 07 | RTD Pt-100 Sensor (3-Wire / 4-Wire) | -80°C to 300°C | National Traceable |
| 08 | S Type Thermocouples with Indicator | 0°C to 1300°C | National Traceable |
| 09 | Dry Block Temperature Calibrator | -35 to 123°C / 50 to 650°C | National Traceable |
| 10 | Deep Freezer Facility | -80°C to 50°C | In-House Calibration Facility |
| 11 | Decade Resistance Box | 0.01 Ω to 11.11 MΩ | National Traceable / ERTL (W) |
| 12 | Digital Multimeter (6.5 Digit) | DC/AC Voltage, Current, Resistance, Frequency | International Traceable / IDEMI |
| 13 | Digital Tachometer Master | 6 to 99,999 RPM | National Traceable |
| 14 | Digital Temperature & Humidity Indicator | 10% to 95% RH, 0°C to 60°C | International Traceable / ERTL (W) |
| 15 | Digital Stopwatch / Timer Standard | Process Duration Verification | National Traceable |
| 16 | Caliper Checker Master | Up to 600 mm | National Traceable |
| 17 | Gauge Blocks ('0' Grade) | 0.5 to 100 mm | National Traceable |
| 18 | Granite Surface Plate ('0' Grade) | 630 x 630 mm Flatness Standard | National Traceable |
| 19 | Digital Vernier Caliper Standard | 0 to 300 mm (L.C. 0.01 mm) | National Traceable |
| 20 | Digital Micrometer Standard | 0 to 25 mm (L.C. 0.001 mm) | National Traceable |
| 21 | Dial Calibration Tester | 0 to 25 mm (L.C. 0.001 mm) | National Traceable |
| 22 | Standard Weights (E2 & F1 Class) | 1 mg to 15 kg (Analytical & Industrial) | National Traceable |
| 23 | pH Meter & Conductivity Standards | 0-14 pH / 0-200 mS/cm Buffer Traceability | National Traceable |
| 24 | Aerosol Photometer (PAO / DOP) | HEPA / ULPA Filter Integrity Verification | National Traceable |
| 25 | Wireless & Wired Data Loggers (21 CFR 11) | -80°C to +1200°C / 0 to 100% RH | National Traceable (±0.5°C) |
Need Custom Scope Verification or On-Site Calibration?
Our technical team responds within 2 hours. Speak directly with Mr. Hitesh P. Mehta or our Lab Incharge today.